CVE-2024-24972

Severity: Medium CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H

Components affected: Controller 6000 and Controller 7000 platforms

Version of Command Centre affected:  

9.10 prior to vCR9.10.240816a (distributed in 9.10.1530 (MR2)), 9.00 prior to vCR9.00.240816a (distributed in 9.00.2168 (MR4)), 8.90 prior to vCR8.90.240816a (distributed in 8.90.2155 (MR5)), 8.80 prior to vCR8.80.240816b (distributed in 8.80.1938 (MR6)), all versions of 8.70 and prior.

Reported by: Gallagher Internal

Active exploitation of vulnerability*: No

Description of vulnerability:
Buffer Copy without Checking Size of Input (CWE-120) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authorised and authenticated operator to reboot the Controller, causing a Denial of Service. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes.

Mitigation: Ensure dipswitch 1 is turned off on all Controllers and the option, "Dipswitch 1 controls the diagnostic web interface", is not checked in Configuration Client on Controller property pages. Do not use the Controller override, "Enable WWW Connections". Refer to the Gallagher Command Centre Hardening Guide for more details.

Maintenance releases are now available for:

  • v9.10 - v9.10.1530(MR2)
  • v9.00 - v9.00.2168(MR4)
  • v8.90 - v8.90.2155(MR5)
  • v8.80 - v8.80.1938(MR6)

Important notes:

*This indicates whether Gallagher are aware of this being actively exploited against customer sites at the time of publication.

Stay up to date with Gallagher

Get the latest Gallagher news, updates, and event information delivered straight to your inbox.